LEVEL MEASUREMENT AND CONTROL IN FLOTATION TANK CELLS

Level measurement and control in flotation tank cells - Sizing method in flotation probes for tank flotation cells, alongside some key installation and operation factors that will assist in ensuring that your LTM-2 probe will provide good and reliable performance.
Details
A single LTM-2 probe can be installed per flotation tank cell. The LTM-2 probe sends a pulp level signal that is utilized by the flotation cell level control system to maintain pulp level depth at setpoint.

Actual pulp level measurement is in the set range below the froth lip height. At the bottom of the bracket is a 40 mm polypropylene bushing to hold the bottom end of the probe steady as well as electronically isolate the probe from the metal bracket. There is no level measurement in the bushing. Therefore, actual maximum possible measuring length is actual probe length-40 mm.

When shipped the full measurement range of the probe is active from the bottom of the probe to the top - calibration in place is required.
The LTM-2 level probe has proven its reliability in various concentrator environments, being used in Column, Bank and Tank flotation cells. The probes have also been tested in various Sump environments